Products
- Home
- Products
Products
Fire Fighting Consulting & Designs
In P360FCAS, We offer a wide range of advanced products to detect, suppress the fire that suits perfectly to the nature of activity taking place in the area.
Kitchen Fire Suppression System
Hazardous Oil and grease fire or Kitchen fires takes place due to overheating of oil in the temperature range of 3500C-3800C which is further enhanced by accumulation of oil deposits in plenum (enclosure behind filter) and exhaust ducts of kitchen hoods over periodic cooking leading to further scope of fire in the smoke extraction system. Reasons for overheating of oil in cooking containers have been found due to temporary distraction by the user or complete absence of attention to cooking appliances/vessels during cooking, for example burners left on by mistake after cooking. It can also occur with malfunctioning of automated temperature control equipment in electrical deep fat fryers. In view of the above referring to annual fire incidents in kitchen and their severity necessitate use of automated kitchen fire suppression with a provision of manual actuation option. The user should evaluate their regional laws of land for requirement of such system.
Protection
⦿ The system incorporates both manual and automatic protection by a heat sensing cable and actuation technique.
⦿ All sensitive areas susceptible to fire such as fire due to overheated cooking oil in vessels/deep fat fryer and oil residual deposits in the extraction system of kitchen hoods are covered by heat sensing cables.
⦿ The system is capable of shutting down other appliances on system actuation, if required.
⦿ Additional equipment such as gas shut off valve, alarm, warning lights etc. can be integrated with the system.
⦿ All sensitive areas susceptible to fire such as fire due to overheated cooking oil in vessels/deep fat fryer and oil residual deposits in the extraction system of kitchen hoods are covered by heat sensing cables.
⦿ The system is capable of shutting down other appliances on system actuation, if required.
⦿ Additional equipment such as gas shut off valve, alarm, warning lights etc. can be integrated with the system.
Panel Fire Suppression System
Most fires are electrical. Fire in Server Racks or electrical panels is generally caused by short circuit or small sparks. In case of fire in such panels/machineries, it is difficult to spot the fire immediately due to enclosed cabinets and hence it’s too late because everything inside has already been destroyed by the fire. Therefore we need instant detection and swift firefighting to fight with such fires. In view of the above referring to annual fire incidents electrical fires, introducing In-Panel Gas Suppression System for Electrical Panels, Enclosed Panels & Server Racks which is a very simple but most effective solution to fight small fires then and there it originates.
Protection
The system incorporates automatic protection by a pneumatic detection and actuation technique. All sensitive areas susceptible to fire such as fire due to sparks in electrical cubical, overheating of cables and sensitive parts/equipment of industrial machinery are covered by Heat Sensing Tube pressurized by dry nitrogen. The Heat Sensing tube is connected to the head of direct low pressure valve mounted on the top of pressurized agent container. The Heat Sensing Tube detects the fire, activates the system and also acts as an extinguishing agent delivery medium. In case of fire, the heat sensing tube ruptures at determined temperature and forms a miniature nozzle which allows releasing the pressure of the tube and operates the direct valve. Extinguishing agent thus released is spread through the heat sensing tube and miniature nozzle.
Total Flooding Gas Supression System
Total flooding system is a clean agent based automatic fixed fire suppression system that achieves extensive coverage. This self-activated system uses advanced technology to achieve maximum extinguishing efficiency and capable to extinguish all types of fire.
The main application of the system is for data centres, server rooms or UPS rooms where important data is stored or expensive material is placed which you cannot afford to lose in case of fire
A fire in areas where electronics are present could not only spell a serious delay for your operations, it can also result in huge financial losses. And putting out the fire doesn’t necessarily spell the end of your troubles either. The reality is, in a fire situation many fire suppression systems cause major damage, and even destroy the very things they are supposed to protect. The need of the hour is a system that works swiftly to contain the fire and extinguish it, ensuring minimal damage. Yet one that’s kind on electronics.
OTHER PRODUCTS
Fire Detection Systems Systems.
Conventional, Addressable and Wireless Smoke Detectors & Alarms.
Fire accidents are very common these days, despite taking a lot of preventive measures. Installing Fire Alarm systems in your commercial buildings can be very helpful. A fire alarm system will detect the fire and send an alarming message that helps take immediate action to stop the fire. There are three types of Alarm systems – Conventional Fire Alarm System, Addressable Fire Alarm System & Wireless Alarm System.
Whether you are planning to get a new alarm system for your building or update your existing alarm, you should first understand the three-alarm systems and the difference between them. Fire Alarms installation can be done better only when you understand it better.
Conventional Fire Alarm Systems:
Just like the name suggests, the Conventional Fire Alarm system uses analog technology to communicate the signals. There are zones, initiating, and notification devices that are connected to a single control panel. Electric currents are used for the communication of the signals to the control panel. When environmental conditions in any given area increase above a specified threshold, then the flow of current in that particular circuit will increase. An alarm is communicated due to this change in the flow of current.
Addressable Fire Alarm Systems:
An Addressable Fire Alarm System works on the digital signal, unlike these Conventional Fire Alarm Systems. The device that is connected to the alarm will send signals in the form of binary code. That means the control panel will receive just zeros and ones. Different types of addressable fire alarms systems are designed to convey different information. So based on these signals, critical information is conveyed to the main control panel. You will gather a lot of information with a digital alarming system compared to analog systems.
Wireless Fire Alarm Systems
Wireless systems are often used in historic buildings where the installation of wired systems is not permitted. Wired systems can however seem the most appealing option as they have a longer history of alerting us to a fire and therefore sending us to safety. We don’t have to worry about battery replacement, although a backup battery is used if power fails. Parts for wireless systems are usually easy to come by. The signal can’t be interfered with in a hard wired smoke detector system either as long as the cabling isn’t damaged.
Temperature Monitoring System
Temperature Monitor & Alarm System
Temperature Monitoring Systems is for remotely monitoring onsite temperature, humidity, power status through wireless GSM Network. When the temperature, humidity, power voltage exceed the high threshold or low threshold value, will send SMS alert to up to 10 preset mobile phone immediately. The GSM Environment Alarm can be used for solar power monitoring, DC power voltage monitoring, temperature monitoring, humidity monitoring, Class Room, Server Rooms, Data Centres, Hospitals.
Fire Protection Devices & Systems
⦿ Fire Extinguishers
⦿ Fire Hydrants
⦿ Fire Sprinkler System